Users Guide: iMFD Sensor Module
Version 1.0 January 23, 2007
Version 1.0 January 23, 2006
www.plxdevices.com
(408)745-7591
iMFD Sensor Module SM-EGT
*Please read the instructions completely through at least once before proceeding with the
installation to minimize errors.
*Double check polarity of power before powering it on for the first time.
Overview:
(Figure 1)
1. Connects to 12V-18V power source.
2. Analog outputs (0-5V linear output)
3. Termination jumper. Closed for first SM in iMFD daisy chain.
4. Connects to next SM in iMFD daisy chain or to first DM
5. Connects to previous SM or unconnected if first SM in iMFD daisy chain
6. Connects to K Type thermo coupler.
Install the Exhaust Gas Temperature Sensor:
1. Install the temperature probe on your header approximately 6-12 inches away from the engine block for best performance.
2. The PLX EGT K Type thermo coupler probe screws into a 1/8 NPT tap.
3. BE CAREFUL, DO NOT OVERTWIST the EGT probe’s wires during installation. This can cause the insulation to come loose
and short the wires internally.
4. Mate the EGT probe with the SM-EGT module where indicated K-Type T.C.
Connecting Power to the Unit:
CAUTION! CONNECTING THE SM-EGT IN REVERSE POLARITY WILL
DAMAGE THE UNIT! CHECK CONNECTIONS BEFORE POWERING ON.
1. The SM-EGT accepts 12-18V DC for power. Connect the negative wire (black) to your vehicle’s ground. This is usually the
negative terminal of your automobile’s battery. Connect the positive wire (red) to your vehicle’s ignition power. This power
is only supplied when your key is turned passed a specific position and is off when your key is removed. Your power
connection must be capable of supplying at least 1 amp of current. A 5 Amp fuse is recommended for safety.
Przeglądanie stron 0
1 2 3 4

Podsumowanie treści

Strona 1

Users Guide: iMFD Sensor Module Version 1.0 January 23, 2007 Version 1.0 January 23, 2006 www.plxdevices.com (408)745-7591 iMFD Sensor Module SM-E

Strona 2

Users Guide: iMFD Sensor Module Version 1.0 January 23, 2006 www.plxdevices.com (408)745-7591 *If you plan to integrate the SM-EGT with other after

Strona 3

Users Guide: iMFD Sensor Module Version 1.0 January 23, 2006 www.plxdevices.com (408)745-7591 Linear Analog Output (0-5V) (Figure 5) Recommended Ac

Strona 4 - Revision History

Users Guide: iMFD Sensor Module Version 1.0 January 23, 2006 www.plxdevices.com (408)745-7591 Specifications: Physical Dimensions 2" x 2.875&

Komentarze do niniejszej Instrukcji

Brak uwag